Product Description

  • Nylon Finger Traps are used for upper extremity traction procedures and the nylon material provides comfort to the patient while in traction
  • The Nylon Finger Trap provides a firm grip, yet are gentle on the patient's skin
  • Reusable and may be sterilized, depending on application
  • Ideal for surgical procedures as well as casting
  • Sold individually
  • Max opening: 1.25"
  • Latex-free
  • Weight Capacity: 20 lbs.
  • Country of Origin: United States of America

Specifications

Specifications
Manufacturer ISI Medical
Item Ships From Texas

Instructions

How to Use: Place patient's fingers in finger traps. Once fingers are secure in traps, place the loop of the finger trap in the appropriate clip on ISI's Digi Grip or other traction device. The traction device may be suspended from an IV pole or traction system. You may also use ISI's Digi Grip, Traction Strap and weight set for additional patient stability.

Sterilization instructions: Clean with any standard disinfectant prior to sterilization. Sterilize the finger trap before each use.

Steam Sterilization General Instructions: Follow standard hospital sterilization practices A. Place clean instruments in an instrument tray B. If instruments are to be wrapped, two double thicknesses of #140 thread count wrappers should be utilized. Exposure times are the same for wrapped or unwrapped instruments C. Follow the instructions for the gravity air displacement steam sterilization listed below.

Gravity Steam Sterilization: A. Double wrap in standard central supply wrap. B. Set the temperature and corresponding exposure time: 121-123 degrees Celsius for 30 minutes.

After cleaning, store in accordance with standard hospital operating procedures to maintain cleanliness. Inspect finger trap before and after each use. If the Finger Trap is split or frayed, do not use. The finger trap should be handled and disposed of in accordance with accepted medical practice and applicable laws and regulations.

Returns

This item is not able to be returned.

Reviews 2

Ask a Question (2)

Customer Questions
If the xl expands to 1.25", how small does it contract?
The minimum width of our XL Finger Trap is .75"
Do you have a instructions for sterilization of this product?
Yes, we have instructions on how to sterilize this item. Please scroll towards the bottom of the page, and you will see the following instructions; Sterilization instructions: Clean with any standard disinfectant prior to sterilization. Sterilize the finger trap before each use. Steam Sterilization General Instructions: Follow standard hospital sterilization practices A. Place clean instruments...
Did you find what you were looking for?