Flexi•holder® FH-410 series significantly reduces retakes caused by improper cassette positioning. It permits smoother scheduling and superior radiographs–saving film, time and labor for cost effective radiographic procedures.

Flexible Arm Movement

  • Radiographs can be taken from any angle from floor level to 71" (180 cm)
  • Tilts cassette 180° facing straight up, straight down or anywhere in between
  • Rotates cassette 360° clockwise or counterclockwise
  • Arm rotates 360° on vertical column
  • Incorporates a ± 90º rotation at the cassette plate
  • Arm assembly is counter-weighted for easy raising or lowering
  • Two models to choose from:
    • Standard Arm telescopes 26" (66 cm) over the X-ray or operating room table
    • Extension Arm telescopes 36" (91 cm) over the X-ray or operating room table

Very Stable, Compact Design

  • Rolls into position on large, locking casters for stable positioning
  • Dimensions: 19" x 22" x 75" (48 x 56 x 191 cm)
  • Product Weight: 110 lbs. (50 kg)
  • Weight limit is approximately 30 lbs

Convenient Ratchet Handles - Ratchet handles can be repositioned easily to help eliminate interference problems when positioning cassettes

Accepts All Cassettes

  • Accepts virtually all cassettes and does not obscure cassette film area
  • Accepts larger cassettes up to 20" (50 cm) wide and up to 1.25" (3 cm) thick

One Hand Operation - A lip on the cassette holder enables the cassette to be inserted with one hand, if necessary

Accurate Calibration Scales - Column and arm calibration scales provide exact, repeatable angulation

Diagnostic Applications

  • Three-way studies of acute abdomens
  • Myelograms
  • Fractures where patient is immobilized
  • Lateral decubitus fluid level studies of abdomen and chest
  • Operating room radiography

Therapeutic Applications

  • Radiation therapy verification films (portal films)
  • Localization for tangential breast, isocentric or oblique fields
  • Simulation without fluoroscopy
  • Implant source localization by orthogonal films

Please note, Agfa® digital cassette shown in photograph is NOT included.

Specifications

Specifications
Country of Manufacture United States
Item Ships From Rhode Island

Returns

Requests for return must be made within 30 days of item receipt. The item must be unused and in all original packaging. To prevent damage in return transit, ideally the unit will not have been assembled prior to return. A minimum 25% re-stock fee is assessed on all returns and all shipping fees remain payable by the buyer.