Product Description

  • ISI DuraHand is reusable and easy to sterilize
  • Withstands multiple sterilizations and manipulations sterilization instructions included
  • Lead-free and Latex-free
  • Allows for the use of X-ray and fluoroscopy
  • Unique Anti-Tilt Tab prevents arm and hand rotation during surgery
  • Made of pliable aluminum with a non-latex coating
  • Affordable
  • Sold individually
  • Large Size: 13" x 10 1/2"
  • Country of Origin: United States of America

Specifications

Specifications
Manufacturer ISI Medical
Item Ships From Texas

Instructions

Always Sterilize DuraHand prior to use. If the DuraHand coating is cracked, discard the device immediately and do not use.

Sterilization Instructions: Device must be cleaned prior to sterilization. The preferred cleaning solution is ISI's Hemaway Tri-Max, but if unavailable, any non-acidic, general purpose cleaner suited for standard surgical instruments is acceptable. The DuraHand should then be autoclaved.

Cycle Type: Pre-Vac Steam Sterilization Full Cycle Instructions

  • Double wrapped in standard central supply wrap
  • Sterilization Temperature: 132°C
  • Sterilization Exposure Time: 4.0 Minutes

Cycle Type: Gravity Steam Sterilization Full Cycle Instructions

  • Double wrapped in standard central supply wrap
  • Sterilization Temperature: 121°C

DuraHand Instructions for Use:

  • Place patient's hand on top the surgical DuraHand
  • Bend wrist tabs over patient's wrist and finger tips over patient's fingers as needed. The patient's hand should then be flat and immobilized. The tab opposite of the thumb can be used as a "kickstand" to prevent the wrist from rolling.
  • After procedure, straighten DuraHand fingers and wrist tabs.
  • DuraHand must be cleaned in accordance with standard institutional protocol prior to sterilization.
  • Sterilize according to "Sterilization Instructions" provided.
  • Handle and dispose of in accordance with accepted medical practice and applicable laws and regulations.

Returns

Products must be returned in unused, unopened, resalable condition with the original packaging. To return this item you must contact Customer Service within 30 days of receipt to obtain a valid Return Authorization Number. Restocking fees may apply at the discretion of the manufacturer. Customers original shipping charges will not be reimbursed. The customer is responsible for return shipping charges and insuring the package. Credit will not be issued if product is received damaged.

Reviews

Ask a Question (1)

Customer Questions
Is the Durahand able to go through standard hospital washers or is handwash the better alternative?
We recommend hand washing the Durihand so it does not exceed exposure temperatures. The preferred cleaning solution is ISI's Hemaway Tri-Max, but if unavailable, any non-acidic, general purpose cleaner suited for standard surgical instruments is acceptable. The DuraHand should then be autoclaved.
Did you find what you were looking for?