The Drucker DASH Flex 24 STAT Centrifuge is designed to meet the needs of large, high-volume STAT laboratories.
Features:
- Features the highest STAT capacity in the DASH centrifuge line
- Combines powerful performance with a compact footprint
- High Capacity STAT - It can spin up to 24 tubes using a variety of different carriers and adapters
- It features a digital display that clearly shows custom parameters and the time left in each cycle
- Fully Programmable - Easily set and save up to 10 custom time, RPM, and g-force settings
- LED lid lighting that indicates cycle status
- Use all 3 presets, or set and lock to a single cycle for maximum repeatability
- Shortens TAT by using a centrifuge array in accessioning
- Safe and durable for worry-free operation with its brushless DC motor and reinforced carbon fiber components
- A shatterproof lid that locks until the centrifuge has stopped completely and opens
- Positive Lid Latching - Firm mechanical latching of the lid prevents the escape of debris
- 2-Stage Horizontal Rotor - Drucker Diagnostics’ patented swing-out horizontal rotor design produces ideal horizontally separated samples
- Cool Operation - Unique design of the convection-based cooling system protects the samples even under the heaviest workloads
- Certified to US, Canadian, and European Safety regulations and standards
- It includes a rotor and a tube holder
Technical Specifications:
- Maximum Capacity: Up to 24 tubes
- Tube Sizes:
- Up to 16 x 100 mm or 10 mL for 24 tubes
- Up to 16 x 125 mm or 15 mL for 12 tubes
- Up to 50 mL for 6 tubes
- Maximum RPM: 4,500 RPM
- Maximum G-Force: 3,450 xg
- Centrifuge Motor: 1/2 H.P. Brushless DC
- Maximum Acceleration Time: 45 seconds
- Maximum Deceleration Time: 40 seconds
- Sound Level: 64 dBA
- Factory Setting Range: 1 to 30 minutes (± 1%)
- Voltage: 100 - 240 (+/- 10%) VAC
- Current Consumption: 3.6 A at 115 VAC, 1.8 A at 230 VAC
- Frequency: 50/60 Hz
- Maximum Power Requirement: 280 W
- Standard Preset Cycles:
- Cycle 1: 3 minutes / 5,200 RPM / 4,000 xg
- Cycle 2: 5 minutes / 5,200 RPM / 4,000 xg
- Cycle 3: 7 minutes / 3,600 RPM / 2,000 xg
- Set-up Site: Indoor use only
- Altitude: Up to 2,000 m from sea level
- Ambient Temperature: 5°C to 40°C
- Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C
- Overvoltage Category: II
- Pollution Degree: 2
- Applications: Blood Chemistry, Pediatric Samples, PPP/Coag, STAT Processing
- Overall Dimensions: 17" D x 15" W x 9" H
- Actual Product Weight: 39 lbs
Specifications
| Manufacturer | Drucker Diagnostics |
|---|---|
| Latex Free | Yes |
| Operating Speed | Up to 4,500 RPM |
| Processing Capacity | 24 samples up to 10 mL, 12 samples up to 15 mL, 6 samples up to 50 mL |
| Power Supply | 100 - 240 (+/- 10%) VAC, 50/60 Hz |
| Actual Product Weight | 39 lbs |
| Overall Height | 9" |
| Overall Width | 15" |
| Overall Depth | 17" |
| Country of Manufacture | United States |
| Item Ships From | Pennsylvania |
Literature
Instructions
Warranty: Drucker Diagnostics warrants that the product, including but not limited to the centrifuge, accessories, and individual components (“Product”), will be free of defects in workmanship and materials for a period of two (2) years from the date of shipment from Drucker Diagnostics. This warranty applies as well to Drucker Diagnostics products sold under private labels.
For Complete Warranty Details, please see the literature above.
Returns
Products must be returned in unused, unopened, resalable condition with the original packaging. To return this item you must contact Customer Service within 30 days of receipt to obtain a valid Return Authorization Number. Restocking fees may apply at the discretion of the manufacturer. Customers original shipping charges will not be reimbursed. The customer is responsible for return shipping charges and insuring the package. Credit will not be issued if product is received damaged.