Product Description

The RSD Multi-Modality Fusion Head Phantom is an anthropomorphic phantom designed for MRI sequence optimization and for validating MRI/CT fusion images through geometric distortion measurements.

Features:

  • Comprehensive Multi-Modality Compatibility - Engineered for precision imaging across MRI, CT, and X-ray modalities
  • High-Fidelity Anatomical Detail - Realistically simulates human skull and cervical spine, crafted from materials replicating trabecular and cortical bone attenuation
  • Advanced Soft Tissue Simulation - For lifelike MRI and CT imaging, the proprietary aqueous solution generates soft tissue signals, allowing for T1, T2, and PD weighted imaging
  • MRI Distortion Evaluation for Stereotactic Radiosurgery (SRS) - Includes an embedded 3D lattice structure within the cranial cavity to assess MRI distortion for SRS planning
  • Accurate Image Fusion and Registration - Versatile verification phantom for image fusion and deformable image registration software across treatment planning systems
  • Optimized Clinical Workflow - Designed to fit perfectly in the Siemens and GE head coil for seamless integration into routine imaging and quality assurance protocols
  • Transparent and Scatter-Resistant Plastic Shell - Encased in a transparent and scatter-resistant plastic shell to ensure structural integrity and contain the aqueous solution securely
  • In MRI, technicians can assess magnetic field distortion by utilizing the 3D printed brain lattice within the cranial section
    • This lattice, filling the entire intracranial space, is composed of 2.5 mm diameter circular rods spaced at 10 mm intervals (I-S), 10.5 mm intervals (AP), and 11 mm intervals (L-R)
    • At the lattice’s center, 5 mm rods establish the x-y-z axes, aiding users in orienting the lattice within the field of view (FOV)
    • Includes MRI/CT compatible markers at the ends of these rods, facilitating co-registration alignment in fused images
  • For CT applications, technicians can evaluate image quality and geometric distortion through the 3D lattice located within the cranium. The high-fidelity anatomical detail holds true across diagnostic and therapeutic energy ranges, spanning from 50 keV to 25 MeV
  • Comes standard with a comprehensive product manual
  • Applications:
    • MRI/CT fusion image verification
    • MRI geometric distortion measurements in small FOV for SRS and diagnostic imaging
    • Teaching and training
    • Image quality
    • Protocol verification and optimization
    • Applicable MRI sequences: T1 FSE, T2 FSE, MPRAGE and CISS, proton density
  • Modalities:
    • MRI
    • CT
    • Cone beam CT
    • X-ray
    • Panoramic X-ray
    • Fluoroscope
    • PET
    • SPECT

About this Brand

Specifications

Specifications
Manufacturer RSD
Latex Free Yes
Country of Manufacture United States
Item Ships From California

Literature

pdf
(Size: 3.3 MB)
pdf
(Size: 401.4 KB)

Instructions

Warranty: Radiology Support Devices, Inc. (RSD) warrants this product (including any accessories) against defects in material or workmanship as follows:

Labor and Parts, for a period of two (2) years from the date of purchase, if this Product is determined to be defective, RSD will repair or replace the Product, at its option, or pay the labor charges to any RSD authorized service facility. After the Warranty Period, you must pay for all labor charges. In addition, RSD will supply, at no charge, new or rebuilt replacements in exchange for defective parts for a period of two (2) years.

For Complete Warranty Details, please see the literature above.