The NIKOTRACE Wet Gel Electrode, Round Shape with Stainless Steel Stud Connectordelivers the clearest, most accurate recordings and comes in a variety of shapes and sizes for precise placement, maximum adhesive coverage, and patient-friendly, long-term monitoring.
Features:
Metal Stud - Guarantees a clean, undisturbed transmission of the 1 mV ECG signal to the monitor. Carbon stud ensures clear transmission and can be used under X-ray without showing a shadow
The backing materials provide a stable base to secure all components and attach securely to the patient
Silver/Silver chloride (Ag/Ag Cl) sensor that delivers fast defibrillation recovery, excellent signal quality, and is required for all ECG monitoring electrodes
Easy-to-find lift tab permits fast removal from cover and easy application and removal from the patient
Electrolyte pad that contains non-irritating, low-impedance gel to produce clear and accurate tracings
A conductive gel that creates an excellent transmission of ECG signal, full surface adhesion, and easy, no-mess cleanup
Super-strong FDA-tested adhesive for clear, long-term ECG monitoring with maximum patient comfort
PVC-, Latex-, and DEHP-free, and biocompatible (ISO 10993)
Recommended for use in stress and Holter monitoring procedures
Technical Specifications:
Backing Material: Foam
Shape: Round
Adhesive Type: Enhanced, Medical Grade
Gel Type: Wet
Sensor: Silver/Silver Chloride (Ag/Ag Cl)
Release Liner: Siliconized PET Film
Connector: Stainless Steel Stud
Regulatory Approvals and Certifications: ISO 13485 Certified, *FDA Registered, *Health Canada Licensed, **CE Mark per 2017/745 EU MDR, and RoHS Directive Compliant
Shelf Life: 24 months
Total Area (mm²): 1964
Adhesive Area (mm²): 1578
Gel Area (mm²): 284
Overall Diameter: 1.97"
*Class II (CFR 21 870.2360 and SOR/98-282, Schedule 1, Rule 7, Subrule 2(b)) **Class I (MDR Annex VIII)
About this Brand
Since 1986, NIKOMED has been a leading supplier of medical devices, including diagnostic and monitoring ECG electrodes, electro-surgical grounding pads, and accessories.
Products must be returned in unused, resalable condition with the original packaging. Please contact Customer Service for a valid return authorization within 30 days of receipt of purchase. A minimum restocking fee of 20% of the purchase price will be deducted from the refund. Customers original shipping charges will not be reimbursed. The customer is responsible for return shipping charges and insuring the package. Credit will not be issued if product is received damaged.