Product Description

Provides standard of reference for Micro-CT scanner
Features:
  • 25 mg/cc - 750 mg/cc HA targets
  • Lung, Muscle and Adipose
  • Optimal for Micro-CT
  • Solid Filled
  • Tissue Equivalent Epoxy Material
  • Country of Origin: United States of America
Micro-CT systems promise to deliver precise and accurate high-resolution measurements. The field of view of these systems requires appropriately scaled QA phantoms.

Provide tools for quantifying calcium and bone density with respect to X-ray attenuation and absorption properties. Hydroxyapatite (HA), the principal constituent of teeth and bones within mammals, is the most appropriate reference for mineral density evaluations. CIRS blends HA in a soft-tissue equivalent, polymer background to provide references which can range in HA loading between 0 mg/cc and 750 mg/cc. Hydroxyapatite grain size and homogeneity of the rods are optimized for use in Micro-CT.

Contain 11 rods of varying mineral loading and dimension. It can be used to evaluate Micro-CT scanners as you would standard whole body scanners. The targets are suitable for determining contrast detectability and estimating low-contrast resolution.

In the MicroMouse Phantom the rods are embedded in soft tissue equivalent material that is of the size and shape of a small rodent.



Specifications:
  • Overall Dimensions: 20 mm + x 60 mm
  • Rod Dimensions:
    • Rods 1 - 6 : 2 mm + x 20 mm
    • Rods 7 - 10: 4 mm + x 20 mm
    • Rod 11: 5 mm + x 10 mm
Component
Composition
Body
Muscle
Rod 1
0 mg/cc
Rod 2
50 mg/cc
Rod 3
100 mg/cc
Rod 4
250 mg/cc
Rod 5
500 mg/cc
Rod 6
750 mg/cc
Rod 7
0 mg/cc
Rod 8
50 mg/cc
Rod 9
250 mg/cc
Rod 10
750 mg/cc
Rod 11
Lung (Low density, inhale)

Specifications

Specifications
Manufacturer CIRS
Item Ships From Virginia
GSA Contract Number V797D-40246

Literature 1

pdf
(Size: 117 KB)

Returns

If you encounter a problem with this item, please contact Customer Service within 14 days of product receipt. If unable to correct the problem, a return material authorization (RMA) number will be issued. Restocking fees may apply at the discretion of the manufacturer. All returns should be packed in the original cases and/or packaging and must include any accessories, manuals and documentation that shipped with the product. The RMA number must be clearly indicated on the outside of each returned package. CIRS recommends that you use a carrier that offers shipment tracking for all returns and insure the full value of your package so that you are completely protected if the shipment is lost or damaged in transit. If you choose not to use a carrier that offers tracking or insure the product, you will be responsible for any loss or damage to the product during shipping. CIRS will not be responsible for lost or damaged return shipments. Return freight and insurance is to be pre-paid.