Product Description

Complete QA from CT imaging to dose verification
Features:
  • Verify heterogeneity corrections
  • Correlate CTU to electron density
  • Check dose distributions in sensitive areas
  • Check depth doses and absolute dose
  • 2D and 3D isodoses
  • Calibrate film with ion chamber
  • Verify individual patient treatment plans
  • Country of Origin: United States of America
Model 002HN IMRT phantom is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and verification of individual patient plans and delivery.

It properly represents human head and neck anatomy in shape, proportion and structure as well as density. This enables thorough analysis of both the treatment planning and delivery systems. The phantom is manufactured from unique proprietary materials that faithfully mimic bone and water within 1% from 50 keV to 25 MeV.

The phantom is circular in shape, approximates the size of an average patient. Tissue equivalent interchangeable rod inserts for ionization chambers allow for point dose measurements in multiple planes in the phantom and film calibration. The phantom also supports film dosimetry with not only standard radiographic films but also Gaf-Chromic® media. Optional inserts are available to support a variety of other detectors including TLD's, MOSFET, and diodes.

Accommodates one Ready Pack 10" x 12" films in transverse orientation, two radiochromic or radiographic 10 x 10 cm films in transverse orientation and a stack of thirteen radiochromic films pre-cut to 63.5 x 63.5 mm in three different orientations.

The surface of the phantom is etched with grooves to ensure proper orientation of the CT slices and accurate film to plan registration.

Model 002HN Includes:
  • One (1) Water equivalent homogeneous section drilled to accommodate rod inserts (15cm)
  • Two (2) Film slabs, 1cm, film cavity 10 x 10 cm with a set of CT to film fiducial markers
  • One (1) Cavity slab, 6.4 cm, to accommodate Film stack or gel cassette
  • One (1) Film Stack for small volume 3D image reconstruction
  • Two (2) Spacer slabs, 1cm
  • One (1) Spacer slab, 2cm
  • One (1) End slab, 1cm
  • One (1) End slab, 1.6 cm
  • Five (5) Water equivalent solid rod inserts
  • One (1) Bone equivalent solid rod insert
  • One (1) Alignment Base
  • One (1) Holding device
Optional Accessories: Set of Four Electron Density Reference Plugs (Item 002ED), Gel dosimetry cassette (Item 002GC), Set of CT to film fiducial markers for additional interfaces (Item 002CTF)

Specifications

Specifications
Manufacturer CIRS
Item Ships From Virginia
GSA Contract Number V797D-40246

Literature 1

pdf
(Size: 93.4 KB)

Returns

If you encounter a problem with this item, please contact Customer Service within 14 days of product receipt. If unable to correct the problem, a return material authorization (RMA) number will be issued. Restocking fees may apply at the discretion of the manufacturer. All returns should be packed in the original cases and/or packaging and must include any accessories, manuals and documentation that shipped with the product. The RMA number must be clearly indicated on the outside of each returned package. CIRS recommends that you use a carrier that offers shipment tracking for all returns and insure the full value of your package so that you are completely protected if the shipment is lost or damaged in transit. If you choose not to use a carrier that offers tracking or insure the product, you will be responsible for any loss or damage to the product during shipping. CIRS will not be responsible for lost or damaged return shipments. Return freight and insurance is to be pre-paid.