Product Description

CT Imaging QA Kit for ATOM Phantoms CIRS700QA

Traditional dosimetry of CT scanners uses standard CTDI phantoms like the CIRS Model 007 CT Dose Phantom. However, more sophisticated CT protocols and continuing equipment improvement require the use of an anthropomorphic phantom of different sizes and/or ages such as the CIRS ATOM family of dosimetry phantoms.

The CIRS CT Imaging QA Kit are suitable for use in CIRS ATOM Dosimetry phantoms and CIRS 007TE Tissue Equivalent CT Dose Phantoms which are already used widely for CT dosimetry. The inserts contained in the kit are designed to investigate correlation between the image quality and CT doses. The kit provides various targets for evaluation of two import CT performance parameters: low contrast detectability and spatial resolution in soft tissues and lung regions.

The Model 700-QA provides four inserts: lung, soft tissue - cylindrical, soft tissue - spherical and soft tissue - true 3D line pair targets. The diameter of the spheres and cylinders were selected to provide a 2:1 volume and cross-sectional area ratios respectively for each adjacent pair of spheres and cylinders. When ordered with ATOM the inserts can be positioned in the abdomen, liver, mediastinum and lung.

Features
  • Determine Low Contrast detectability
  • Evaluate spatial resolution
  • Use in ATOM or CIRS 007TE phantoms
  • 3 soft tissue inserts
  • 1 lung insert
  • Country of Origin: United States of America

Specifications

Specifications
Manufacturer CIRS
Item Ships From Virginia
GSA Contract Number V797D-40246

Literature 1

pdf
(Size: 111 KB)

Returns

If you encounter a problem with this item, please contact Customer Service within 14 days of product receipt. If unable to correct the problem, a return material authorization (RMA) number will be issued. Restocking fees may apply at the discretion of the manufacturer. All returns should be packed in the original cases and/or packaging and must include any accessories, manuals and documentation that shipped with the product. The RMA number must be clearly indicated on the outside of each returned package. CIRS recommends that you use a carrier that offers shipment tracking for all returns and insure the full value of your package so that you are completely protected if the shipment is lost or damaged in transit. If you choose not to use a carrier that offers tracking or insure the product, you will be responsible for any loss or damage to the product during shipping. CIRS will not be responsible for lost or damaged return shipments. Return freight and insurance is to be pre-paid.