Product Description

Softcare Replacement Armboard Pads offer the following features:

  • Size: 26" x 6"
  • Foam: Latex Free Top Layer of Memory Foam (6 lb density), Bottom Layer: Latex Free High Density Polyfoam (1.8 lb density)
  • Cover Material: Latex Free, black, conductive, urethane coated, 4 way stretch-knit fluid proof cover
  • Cover Seams: Fluid Resistant. Seams are sewn using waterfall technology, a top cover pattern where the top edges have as few seams as possible. Fluids should roll over the top edges without dwelling in the seam areas.
  • Radiolucent for artifact free imaging.
  • Includes VELCRO®
  • Warranty: 2 years on manufacturer defects
  • Returns: Not allowed on this item as it is custom made to your table specifications & thickness request.

About this Brand

Specifications

Specifications
Manufacturer Universal Medical Inc.
GSA Contract Number V797D-40002

Instructions

CLEANING OF SOILS & STAINS: Do not use products or methods that are not listed below. Do not Apply tape to any Pad.

  • Wash with a generous application of neutral soap suds and lukewarm water. Rinse with water and dry. Do not immerse.

OR

  • Use a diluted bleach solution of 10-parts water to 1-part bleach. Wipe dry with a clean cloth. Do not immerse. Bleach MUST be diluted to the 10:1 ratio.

All chemicals/solutions MUST be diluted to the manufacturers recommendations. No chemical or solution should be left to dry on the pad surface. After the allotted time has passed to insure disinfection, the pad surface should be wiped again with a wet cloth to remove the remaining chemical or solution.

DISINFECTING: Do not use products or methods that are not listed below. Do not Apply tape to any Pad.

  • Use Lysol I.C. Disinfectant Spray by National Laboratories, Montvale, NJ, per manufacturer's instructions. Reference: National Laboratories Item # 95029-000
OR
  • Use a diluted bleach solution of 10-parts water to 1-part bleach. Wipe dry with a clean cloth. Do not immerse. Bleach MUST be diluted to the 10:1 ratio.

All chemicals/solutions MUST be diluted to the manufacturers recommendations. No chemical or solution should be left to dry on the pad surface. After the allotted time has passed to insure disinfection, the pad surface should be wiped again with a wet cloth to remove the remaining chemical or solution.

Returns

This item is non-returnable. It is custom made to your table specifications and thickness requirements.